| Construction Details | |
| Conductor | |
| Size | 24 AWG |
| Stranding | Solid |
| Material | BC - Bare Copper |
| No. of Pairs | 4 |
| Insulation | |
| Material | Color Code |
| PO - Polyolefin | White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown |
| Outer Jacket | |
| Material | PVC - Polyvinyl Chloride |
| Nom. Diameter | 0.190 in (4.83 mm) |
| Ripcord | Yes |
| Overall Cable Diameter (Nominal) | 0.190 in (4.83 mm) |
| Electrical Characteristics | |
| Electricals | |
| Max. Conductor DCR | 93.8 Ohm/km (28.6 Ohm/1000ft) |
| Max. Capacitance Unbalance | 330 pF/100m |
| Delay | |
| Frequency | 100 MHz |
| Max. Delay | 537.6 ns/100m |
| Max. Delay Skew | 45 ns/100m |
| Nom. Velocity of Prop. | 70% |
| Voltage | |
| UL Voltage Rating | 300 V (CMR) |
| Mechanical Characteristics | |
| Temperature | |
| UL Temperature | 75°C |
| Operating | -20°C To +75°C |
| Installation | 0°C To +50°C |
| Storage | -20°C To +75°C |
| Bend Radius | |
| Stationary Min. | 1.0 in (25 mm) |
| Installation Min. | 2.0 in (51 mm) |
| Max. Pull Tension | 25 lbs (11 kg) |
| Bulk Cable Weight | 18 lbs/1000ft |
Note:
Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 100 MHz are for Engineering Information Only. Print Includes Descending Footage Markings from Max. Put-Up Length to 0.