LHS

2100A

Product Number : 2100A

Fieldbus, 1 Pr #18 Str TC, XLPO Ins, OS, TPE Jkt, CMG

Fieldbus, 1 Pair 18AWG (7×26) Tinned Copper, XLPO Insulation, Overall Beldfoil® Shield, TPE Outer Jacket, CMG
WhatsApp us

This product is currently out of stock and unavailable.

Physical Characteristics (Overall)
Conductor
AWG 18
Stranding 7x26
Material TC - Tinned Copper
No. of Pairs 1
Conductor Count 2
Total Number of Pairs 1
Insulation
Material XLPE - Cross-Linked Polyethylene (Thermoset)
Color Chart
Number 1
Color Blue, Orange and Numbered
Outer Jacket
Material TPE - Thermoplastic Elastomer
Nominal Diameter 0.319 in
Ripcord Yes
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR 5.86 Ohm/1000ft
Capacitance
Max. Capacitance Unbalance 1.2 pF/ft
Nom. Capacitance Conductor to Shield 22 pF/ft
Inductance
Nominal Inductance 0.22 µH/ft
Impedance
Nominal Characteristic Impedance 100 Ohm
High Frequency (Nominal/Typical)
Nom. Insertion Loss 0.08 dB/100ft
Delay
Nominal Velocity of Propagation (VP) [%] 64%
High Frequency
Max. Insertion Loss (Attenuation) 0.091 dB/100ft
Max./Min. Input Impedance (unFitted) 100 Ohm
Current
Element Per Conductor
Max. Recommended Current [A] 8.7 Amps per Conductor
Voltage
Description CSA CIC type TC
UL Voltage Rating 300 V
Voltage Rating [V] 300 V RMS
Electrical Characteristics Notes Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft
Other Electrical Characteristic 2 31.25 KBits/sec
Temperature Range
Installation Temp Rating -25°C
Installation Temperature Range -25°C
UL Temp Rating 90°C Wet/Dry
Operating Temperature Range -25°C Cold Impact -40°C to +90°C -55°C Cold Bend
Mechanical Characteristics
UV Resistance Yes
Bulk Cable Weight 51 lbs/1000ft
Max. Pull Tension 57 lbs
Min. Bend Radius/Minor Axis 3.25 in
Suitability
Suitability - Indoor Yes
Suitability - Oil Resistance Yes
Suitability - Outdoor Yes
Suitability - Sunlight Resistance Yes

Product Overview

Suitable Applications: 

harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Standards

NEC Articles

Article 725, Article 727, Article 800

NEC/(UL) Compliance

CMG, ITC, PLTC-ER

CSA AWM Compliance

AWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC

Scroll to Top