| Physical Characteristics (Overall) | |
| Conductor | |
| AWG | 18 |
| Stranding | 7x26 |
| Material | TC - Tinned Copper |
| No. of Pairs | 1 |
| Conductor Count | 2 |
| Total Number of Pairs | 1 |
| Insulation | |
| Material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Color Chart | |
| Number | 1 |
| Color | Blue, Orange and Numbered |
| Outer Jacket | |
| Material | TPE - Thermoplastic Elastomer |
| Nominal Diameter | 0.319 in |
| Ripcord | Yes |
| Electrical Characteristics | |
| Conductor DCR | |
| Nominal Conductor DCR | 5.86 Ohm/1000ft |
| Capacitance | |
| Max. Capacitance Unbalance | 1.2 pF/ft |
| Nom. Capacitance Conductor to Shield | 22 pF/ft |
| Inductance | |
| Nominal Inductance | 0.22 µH/ft |
| Impedance | |
| Nominal Characteristic Impedance | 100 Ohm |
| High Frequency (Nominal/Typical) | |
| Nom. Insertion Loss | 0.08 dB/100ft |
| Delay | |
| Nominal Velocity of Propagation (VP) [%] | 64% |
| High Frequency | |
| Max. Insertion Loss (Attenuation) | 0.091 dB/100ft |
| Max./Min. Input Impedance (unFitted) | 100 Ohm |
| Current | |
| Element | Per Conductor |
| Max. Recommended Current [A] | 8.7 Amps per Conductor |
| Voltage | |
| Description | CSA CIC type TC |
| UL Voltage Rating | 300 V |
| Voltage Rating [V] | 300 V RMS |
| Electrical Characteristics Notes | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
| Other Electrical Characteristic 2 | 31.25 KBits/sec |
| Temperature Range | |
| Installation Temp Rating | -25°C |
| Installation Temperature Range | -25°C |
| UL Temp Rating | 90°C Wet/Dry |
| Operating Temperature Range | -25°C Cold Impact -40°C to +90°C -55°C Cold Bend |
| Mechanical Characteristics | |
| UV Resistance | Yes |
| Bulk Cable Weight | 51 lbs/1000ft |
| Max. Pull Tension | 57 lbs |
| Min. Bend Radius/Minor Axis | 3.25 in |
| Suitability | |
| Suitability - Indoor | Yes |
| Suitability - Oil Resistance | Yes |
| Suitability - Outdoor | Yes |
| Suitability - Sunlight Resistance | Yes |
2100A
Product Number : 2100A
Fieldbus, 1 Pr #18 Str TC, XLPO Ins, OS, TPE Jkt, CMG
Fieldbus, 1 Pair 18AWG (7×26) Tinned Copper, XLPO Insulation, Overall Beldfoil® Shield, TPE Outer Jacket, CMG
WhatsApp us
Product Overview
Suitable Applications:
harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.
Standards
|
NEC Articles |
Article 725, Article 727, Article 800 |
|---|---|
|
NEC/(UL) Compliance |
CMG, ITC, PLTC-ER |
|
CSA AWM Compliance |
AWM I A/B II A/B, C22.2 #230 Type TC; C22.2#239 Type CIC |