| Physical Characteristics (Overall) | |
| Conductor | |
| AWG | 26 |
| Stranding | 7x34 |
| Material | TC - Tinned Copper |
| Nominal Diameter | 0.019 in |
| No. of Pairs | 8 |
| Conductor Count | 16 |
| Insulation | |
| Material | PE - Polyethylene (Foam) |
| Material Trade Name | Datalene® |
| Nominal Diameter | 0.054 in |
| Nominal Wall Thickness | 0.0175 in |
| Color Chart | |
| 1 | Brown and Numbered 1 |
| 2 | Red and Numbered 2 |
| 3 | Orange and Numbered 3 |
| 4 | Yellow and Numbered 4 |
| 5 | Green and Numbered 5 |
| 6 | Blue and Numbered 6 |
| 7 | Purple and Numbered 7 |
| 8 | Gray and Numbered 8 |
| Inner Shield | |
| Type | Tape |
| Material | Bi-Laminate (Alum+Poly) |
| Material Trade Name | Beldfoil® |
| Coverage (%) | 100% |
| Drainwire Material | TC - Tinned Copper |
| Table Notes | Indiv. Foil tapes bonded to inner jacket |
| Inner Jacket | |
| Material | PVC - Polyvinyl Chloride |
| Nominal Diameter | 0.136 in |
| Nominal Wall Thickness | 0.014 in |
| Outer Shield | |
| Type | Tape |
| Material | Bi-Laminate (Alum+Poly) |
| Material Trade Name | Beldfoil® |
| Coverage [%] | 100% |
| Drainwire Material | TC - Tinned Copper |
| Outer Jacket | |
| Material | PVC - Polyvinyl Chloride |
| Nominal Diameter | 0.541 in |
| Nominal Wall Thickness | 0.044 in |
| Ripcord | Yes |
| Electrical Characteristics | |
| Conductor DCR | |
| Individual Pair Nominal Shield DCR | 25.5 Ohm/1000ft |
| Nominal Conductor DCR | 37.3 Ohm/1000ft |
| Nominal Conductor DCR Conductor Resistance | 37.3 Ohm/1000ft |
| Capacitance | |
| Nom. Capacitance Conductor to Conductor | 13 pF/ft |
| Nom. Capacitance Conductor to Other Conductor to Shield | 25 pF/ft |
| Inductance | |
| Nominal Inductance | 0.25 µH/ft |
| Impedance | |
| Nominal Characteristic Impedance | 110 Ohm |
| Delay | |
| Nominal Velocity of Propagation (VP) [%] | 76% |
| Temperature Range | |
| Operating Temperature Range | -30°C To +80°C |
| Mechanical Characteritics | |
| Bulk Cable Weight | 100 lbs/1000ft |
| Max. Pull Tension | 84 lbs |
| Min. Bend Radius/Minor Axis | 5.5 in |
| Standards | |
| NEC/(UL) Compliance | CM |
| CEC/C(UL) Compliance | CM |
| CPR Euroclass | Eca |
| Applicable Environmental and Other Programs | |
| Environmental Space | Indoor (Not Riser or Plenum) |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| EU CE Mark | Yes |
| MII Order #39 (China RoHS) | Yes |
| Plenum / Non-Plenum | |
| Plenum (Y/N) | No |
Note:
Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight.